• <tr id='pRecth'><strong id='pRecth'></strong><small id='pRecth'></small><button id='pRecth'></button><li id='pRecth'><noscript id='pRecth'><big id='pRecth'></big><dt id='pRecth'></dt></noscript></li></tr><ol id='pRecth'><option id='pRecth'><table id='pRecth'><blockquote id='pRecth'><tbody id='pRecth'></tbody></blockquote></table></option></ol><u id='pRecth'></u><kbd id='pRecth'><kbd id='pRecth'></kbd></kbd>

    <code id='pRecth'><strong id='pRecth'></strong></code>

    <fieldset id='pRecth'></fieldset>
          <span id='pRecth'></span>

              <ins id='pRecth'></ins>
              <acronym id='pRecth'><em id='pRecth'></em><td id='pRecth'><div id='pRecth'></div></td></acronym><address id='pRecth'><big id='pRecth'><big id='pRecth'></big><legend id='pRecth'></legend></big></address>

              <i id='pRecth'><div id='pRecth'><ins id='pRecth'></ins></div></i>
              <i id='pRecth'></i>
            1. <dl id='pRecth'></dl>
              1. <blockquote id='pRecth'><q id='pRecth'><noscript id='pRecth'></noscript><dt id='pRecth'></dt></q></blockquote><noframes id='pRecth'><i id='pRecth'></i>
                BD-6000 Infusion Pump
                Time2018-7-6 15:52:05Access
                BD-6000 Infusion Pump

                Brand Meditech infusion pump Model: BD-6000

                Brand Meditech Model: BD-6000 infusion pump technique specifications

                Infusion rate range: 1-600 ml/h

                Bolus rate range: 600ml/h

                Double CPU monitoring board, free-door design

                Preset infusion range: 1-9999 ml

                Accumulated volume: 0.1-9999.9ml

                Increment: 1, 10, and 100
                KVO rage: 1ml/h
                (KVO occur after OCCL. alarm)

                Infusion accuracy: 5% (after being adjusted, up to 2%)

                Power supply: Widescreen power switch (AC100-240V0), 50Hz/60Hz, fuse, T 2AL 250V

                Battery: Rechargeable lithium polymer battery, 8.4V, 1600mA, when infusion pump is connected to AC power, the battery will start charging automatically

                Max power consumption: 25VA, it can work for more than 4 hours (25ml/h) after being fully charged.

                Infusion pump mechanism: creep mechanism

                Applicable infusion set: national standard infusion set

                Applicable standards: GB/T191-2008, GB8368-2005, GB9706.1-2007, GB9706.27-2005, GB9969.1, GB/T14710-1993, YY0466-2003
                Applicable Environmental condition: Environmental temperature:+5
                --+40, air pressure:(860--1060)hPa, relative humidity:20%--80%

                Displayed information: battery symbol, connect symbol, infusion set symbol, flow rate, flow rate value and unit, preset value, preset value and unit, Accumulated volume, accumulated volume& unit, over, occlusion, air bubble, bed No., pressure value etc.

                Status indication information: Stop. Run, Bolus, KVO

                Alarm function: Over, occlusion, air bubbles, installation error of infusion pipe, abnormal control, no AC power supply, low pressure and serious low battery.
                Air Bubble Detection: At the rate of 600ml/h, the smallest bubbles that can be detected are 0.005ml of volume
                Infusion Pressure: Maximum pressure is 300kPa; occlusion gate value is 39.2kPa-137.2kPa.The longest time to give occlusion alarm is 2 minutes at rate of 25ml/h. And at rate of 5ml/h is 5 minutes.

                Weight: Less than 1.8kg

                Classification: Class II, type BF

                Outer Shell Material: ABS Plastic
                Waterproof grade: IP21

                 